Victron Phoenix Inverter 12/250 - 120V - VE.Direct NEMA 5-15R - Single Outlet - 200W [PIN122510500]
Victron Phoenix Inverter 12/250 - 120V - VE.Direct NEMA 5-15R - Single Outlet - 200W [PIN122510500]
Victron Phoenix Inverter 12/250 - 120V - VE.Direct NEMA 5-15R - Single Outlet - 200W [PIN122510500]

Victron Phoenix Inverter 12/250 - 120V - VE.Direct NEMA 5-15R - Single Outlet - 200W [PIN122510500]

$96.90 USD $114.00 USD /
Subscription -

Phoenix Inverter 12/250 - 120V - VE.Direct NEMA 5-15R - Single Outlet - 200W

Inverters allow users to power domestic equipment - requiring 230V/120V AC - using 'leisure' or 'automotive' batteries rated at 12V, 24V or 48V DC. 

*This inverter has a NEMA 5-15R outlet. 

E.Direct Communication Port

The VE.Direct port can be connected to:

  • A computer (VE.Direct to USB interface cable needed)
  • Apple and Android smartphones, tablets, MacBook, and other devices
  • (VE.Direct Bluetooth Smart dongle needed)

Fully Configurable:

  • Low battery voltage alarm trip and reset levels
  • Low battery voltage cut-off and restart levels
  • Dynamic cut-off: load-dependent cut-off level
  • Output voltage 210 - 245V
  • Frequency 50 Hz or 60 Hz
  • ECO mode on/off and ECO mode sense level

Monitoring:

  • In- and output voltage, % load, and alarms

Proven Reliability

The full bridge plus toroidal transformer topology has proven its reliability over many years.

The inverters are short-circuit proof and protected against overheating, whether due to overload or high ambient temperature.

High Start-Up Power

Needed to start loads such as power converters for LED lamps, halogen lamps, or electric tools.

ECO Mode

When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once on standby, the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.

Remote On/Off

A remote on/off switch can be connected to a two-pole connector, or between battery plus and the left-hand contact of the two-pole connector.

LED Diagnosis

Please see the manual for a description.

To Transfer the Load to Another AC Source: The Automatic Transfer Switch

For Victron’s low-power inverters, they recommend the Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption. 

Inverter Specifications:

  • Cont. Power at 25 degrees C: (1) 250VA 
  • Cont. Power at 25 degrees C / 40 degrees C: 200 / 175W 
  • Peak Power: 400W 
  • Output AC Voltage / Frequency (adjustable): 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%
  • Input Voltage Range: 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V
  • DC Low Shut Down (adjustable): 9,3 / 18,6 / 37,2V
  • Dynamic (load dependent) DC Low Shut Down (fully configurable): Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
  • DC Low Restart & Alarm (adjustable): 10,9 / 21,8 / 43,6V
  • Battery Charged Detect (adjustable): 14,0 / 28,0 / 56,0V
  • Max. Efficiency: 87 / 88 / 88% 
  • Zero-Load Power: 4,2 / 5,2 / 7,9W 
  • Default Zero-Load Power in ECO Mode (default retry interval: 2,5 s, adjustable): 0,8 / 1,3 / 2,5W 
  • ECO Mode Stop & Start Power Setting: Adjustable
  • Protection (2): a - f
  • Operating Temperature Range -40 to +65 degrees C (fan-assisted cooling) 

Enclosure Specifications:

  • Material & Color: Steel chassis and plastic cover (blue Ral 5012)
  • Battery-Connection: Screw terminals
  • Maximum Cable Cross-Section: 10mm² / AWG8 
  • Standard AC Outlets: 230V: Schuko (CEE 7/4), IEC-320 (male plug included); UK (BS 1363), AU/NZ (AS/NZS 3112); 120V: Nema 5-15R, GFCI
  • Protection Category: IP 21
  • Weight: 2,4kg / 5,3lbs 
  • Dimensions (H x W x D, mm); (H x W x D, inch): 86 x 165 x 260; 3.4 x 6.5 x 10.2

Accessories:

  • Remote On-off: Yes
  • Automatic Transfer Switch: Filax

Standards:

  • Safety: EN-IEC 60335-1 / EN-IEC 62109-1 / UL 458 (3)
  • EMC: EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3
  • Automotive Directive ECE R10-4: 1) Nonlinear load, crest factor 3:1; 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) DC ripple too high
Please contact your dealer for any returns, repairs or support issues related to this product.

Specifications:

  • GFCI: No
  • Box Dimensions: 6"H x 9"W x 12"L WT: 6.6 lbs
  • UPC: 8719076035954

Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)
Only 9 In stock